Tuesday, 13 September 2016

@DDCL, @Edmonton, @Handyman Services sealing of cracked concrete.

This garage has a water leak. The leaky joint is in the process of being sealed. By the end of of today the leak should be no more. If you have foundation leaks in your garage contact our representative Daniel at 587-597-4228. Have a great day.

Sunday, 11 September 2016

@DDCL, @Edmonton, @HandymanServices Central Vacuum


Central Vacuum Attachments or Connections in Buildings Using Electrical Tape vs Electrical Nuts

Increasing voltage and amperage to electrical devices increases the risk potential shorts and electrical fire hazards if electrical tape is used to hold and insulate the bare electrical wire end.

Electrical connections should be sound firm connections by using the appropriate components such as electrical nuts for the particular wire size and quantity of wires. If electrical tape is used to cover the wires as the voltage and amperage increase the potential of burn through the electrical tape increases. The ends of the wire when cut have sharp edges and as tape is wrapped around the wire stretch and thin out. Most of all the electrical tape will deteriorate over time. Electrical nuts are designed to hold the wires together and have a solid protective coating to prevent shorts, burn through and maintain a tight connection among the wires joined.

When central vacuum connection are failing intermittently after years of use from connecting and disconnecting it is time to inspected and resolve your issue. If twisting the hose connection from side to side to make the central vacuum start-up it is possible that the hose end is failing, wires connections could be broken / disconnected or the connection itself is broken. Once should never forget that pipes could also be plugged, broken or even disconnected.

The only way to determine your particular issue is to systematically trouble shoot.

We could possibly resolve your central vacuum issues so contact DDCL’s Representative Daniel at 587-597-4228. Have a great days and see you next time.
Vacuum Fixture, Broken Fixture

Friday, 9 September 2016

@DDCL, @Edmonton, @HandymanServices sealing of concrete cracks.

The project today was to stop a water leaking into the garage at the footing wall interface. The water is leaking approximately six feet along one side of the garage on the inside. The ground along the outside wall was removed down to the footing and inspected for holes, cracks, wood in seams or anything else that might be an issue.

Originally when the soil was added a section of the seam was not sealed with the protective barrier which caused the leak. Big Blue is added along the wall footing interface after following  manufacturers recommendations.

On this side of the garage the soil is a bit saturated with water so a secondary protection system is going to be installed to remove excess water from the immediate area.

If you have foundation leaks in your garage contact our representative Daniel at 587-597-4228. Have a great day.
Removal of Soil,                              Preparation of the Cement                               Big Blue, Primary Protection






@DDCL, @Edmonton, @Electrical nicked electrical wires in outlet boxes.

Well working in Edmonton and replacing a bathroom ceiling fan. The installation went well up to the point where I found out the fan run all the time. This was strange because I just replace the fan unit so the cover was removed and took a wee peek. Electrical tape was seen wrapped around the common "white wire" and load "black wire". Both wires were not completely covered with electrical tape. Another wire was cut off in the box and the end was not covered with a electrical nut. This could cause a electrical short or worse. The switch for the fan now works properly. Always appreciate the business and look forward to challenges which tomorrow brings. At DDCL there are no jobs too small. Contact Daniel our representative at 587-597-4228. We have a book keeping service completed by book keepers and a cleaning service for residential or commercial settings. Have s great evening everyone.

Wire is hooked like a chain, Electrical tape wrapped around the wire, Load wire is cut & has open end

Thursday, 1 September 2016

@DDCL, @Edmonton, @HandymanServices, Daniel, DDCL 587-597-4228 Integrity of ones workmanship


Integrity is the word which fits I do believe.

For all those out there who complete jobs no matter what the task is or the amount of compensation you get do the best you can. Your compensation will come in long term dividends when you do a good job and people call you back to do other jobs.

When leveling the shed the support beam were not sufficient to stop the shed from flexing mid-way along the length. Entering the shed many screw heads were stripped, had gaps from the base of the screw to the mating plastic surface. Workers who are proud of their work would replace the screws and ensure the screw joint ends up as designed. Yes, integrity of the person who put the shed together. It might be that the compensation was not great enough to fix issues and maybe the owner would not see the craftsmanship. There are many people out there who do an excellent job. It could be that the cold and hot weather “expansion and contraction forces” caused some issues. But the stripped screws do not fall in the category here. The bit could have been worn out but in this case should have been replaced. In my opinion the supplier should be contacted and fix issues which are found by the owner, within reason.

There are some times when completing a job nothing goes as planned and this is the time to take a step back and regroup even if you have to leave it for a few hours or the next day. One should always guarantee his or her workmanship. Doing work for others and expecting huge compensation packages is unreasonable for the owner could be anyone and you might be on the receiving end in the future.

Here is a picture of one of a few incorrect screw attachments, there are others which almost fell out or had stripped heads as mentioned previously. While on this job unfortunately the peek plastic was broken so it was taped over to help in preventing rain from entering. I would have thought that there would also be end caps to keep the insects out but none were seen. O boy all these little repairs take time and I honestly believe that we will all be compensated in the future by being fair to all clients.

Have a great day from all of here at DDCL.

Tuesday, 9 August 2016

@DDCL, @Edmonton,@Plumbing repairing of broken sewer lines.

Well as the line was dug up and cut for replacement it was found the line was still full. The line may of collapsed but it definitely full of bad stuff inside of the basement. So knowing the pipe is still plugged in all of the basement outside of the basement will have to be dug up starting at the property line which is half way to the the centre of the road where the man hole is.   Hopefully this is as far as what needs to be done. One has to step through the process of repair. This is just one of the types of projects which we do here at DDCL. If you have a project which needs to be done contact Daniel at 587-597-4228.
One call of ATCO gas has marked their lines already and now ATCO electric will be back in the morning to locate the electrical lines. Doing my due diligence by calling in one call. The digging will start tomorrow outside.



Saturday, 6 August 2016

@DDCL, @Edmonton, @ HandymanServices, Daniel 586-597-4228, Trim added to an older house- white paint to be added

Just working on an older house today putting trim boards on an uneven  hardwood floor. the trim is going to be painted white, so to make hide the uneven floor. The helper put on the silicone and is going to paint the trip later tonight or in the morning.
Glad to see this part of the project completed and if you need this type of work done at your place call Daniel our representative at 587-597-4228.